Indian Cables & Electricals Pvt. Ltd is a authorized distributors of POLYCAB COAXIAL CABLES in Pune, Maharashtra.
JELLY FLOODED COAXIAL CABLES

Polycab, the market leaders in Power & Control Cables and Fastest growing Company in the Cable industry,offer the widest range of cables and wires in the country. Polycab Coaxial Cables for Cable TV Network are manufactured at its ultra modern plant at Daman. The stringent quality control measure coupled with Company’s R&D efforts ensure production of Coaxial Cables that are technologically superior and provide an ideal combination of electrical Cables the preferred choice fora variety of applications in CATV network.

The center conductor is made of solid electrical grade 99.97 pure copper to ensure better signal transmission. The conductor is insulated with nitrogen gas, which is superior and environment friendly as compared to chemical foam. The double screen of special composite type bonded aluminium foil and special grade aluminium alloy branding of 60 % coverage ensure low loss in signal quality, additional mechanical strength and resistance to oxide formation in tropical whether conditions. The specially in-house formulated PVC compound used in the jacketing is UV and abrasion resistant.

Polycab Coaxial Cables are fully tested for all parametres by computerized analyzer. Coaxial cables with steel wire armouring can also be supplied for underground applications.

FEATURES & ADVANTAGES
• Minimum loss in signal quality : better reception
• Higher band width : larger network expansion, 100 plus channels
• Low attenuation value : less electromagnetic interference
• Minimum structural return loss

ELECTRICAL PARAMETERSRG 11FCABLE TYPE RG 6FRG 59F
Center conductor
(Max. resistance at 20°)
0.85 ohm/100mtr.2.14 ohm/100 mtr.3.55 ohm/100mtr.
Nom. Capacitance (PF/Mtrs.)53 + 353 + 353 + 3
Characteristics Impendance (ohms)75 + 375 + 375 + 3
Nom,Velocity Ratio (%)858585

Attenuation @ 20′ c

(db/100 Mtrs.) at

   
5 MHZ1.25 db1.95 db2.82 db
55 MHZ3.15 db5.20 db6.73 db
211 MHZ6.23 db9.50 db12.47 db
250 MHZ6.72 db10.50 db13.45 db
300 MHZ7.38 db11.50 db14.60 db
350 MHZ7.94 db12.45 db15.75 db
400 MHZ8.53 db13.30 db16.73 db
450 MHZ9.02 db14.35 db17.72 db
550 MHZ9.97 db15.70 db19.52 db
600 MHZ10.43 db16.45 db20.34 db
750 MHz11,97 db18.35 db22.87 db
865 MHZ13.05 db19.95 db24.67 db
1000 MHz14.27 db21.45 db26.64 db
• Moisture proof : Ideal for tropical conditions
CONSTRUTION   PARAMETERSRG 11FCABLE TYPE RG 6FRG 59F
CENTER CONDUCTORsolid bare coppersolid bare coppersolid bare copper
Nom. Dia. (mm)1.631.020.80
DIELECTRIC
Nom. Dia.(mm)
Foam PE
7.11
Foam PE
4.57
Foam PE
3.55

OUTER CONDUCTOR

1st Shield
2nd Shield
Min. Coverage (%)

Al-Foil Bonde
Al-Alloy Branding
60
Al-Foil Bonde
Al-Alloy Branding
60
Al-Foil Bonde
Al-Alloy Branding
60
Flooding CompoundJellyJellyJelly
JACKET
Nom. Dia. (mm)
PVC Black
10.30
PVC Black
7.25
PVC Black
6.20
BENDING RADIUS (mm)706060

Information Source – Polycab